SBIR-STTR Award

Spatially Integrating Optical Magnetometer (S-IOM)
Award last edited on: 6/5/2023

Sponsored Program
SBIR
Awarding Agency
DOD : Navy
Total Award Amount
$1,339,981
Award Phase
2
Solicitation Topic Code
N192-122
Principal Investigator
Christopher Rey

Company Information

Energy to Power Solutions (AKA: E2P Solutions~Tai-Yang Research Co)

3958 West Pensacola Street
Tallahassee, FL 32304
   (866) 250-0237
   sales@e2pco.com
   www.e2pco.com
Location: Single
Congr. District: 05
County: Leon

Phase I

Contract Number: N68335-20-C-0176
Start Date: 11/7/2019    Completed: 3/4/2021
Phase I year
2020
Phase I Amount
$239,998
Energy to Power Solutions (e2P) of Tallahassee, FL proposes to design, fabricate, and test an integrated B-field sensor that meets and in some cases exceeds the requirements set for the N192-122 solicitation topic using our proprietary Integrated Magnetometer (IM) developed under an earlier U.S. Department of Energy (DOE) program. The goal of the proposed effort is to make several modifications to e2Ps existing IM that will enhance the sensitivity of the device in order to meet the Navys requirements.

Benefit:
An anticipated potential commercial market opportunity for this technology is in proton therapy in the healthcare field. Proton therapy is now commonly used for the treatment of certain types of cancers. These proton therapy centers rely on compact curved accelerators with multiple C-shaped dipole magnets for beam steering. Since it is the ?Bdl measurement that is most important, e2Ps proposed Integrated Magnetometer could play an important role.

Keywords:
Degaussing, Degaussing, magnetic field, measurement sensors

Phase II

Contract Number: N68335-21-C-0313
Start Date: 5/6/2021    Completed: 2/22/2024
Phase II year
2021
Phase II Amount
$1,099,983
The U.S. Navy is currently using a Closed Loop Degaussing Systems (CLDG) on their Virginia-class and their future planned Columbia-class submarines to reduce their overall magnetic signature to make them less vulnerable to detection. The current CLDG systems on the Virginia-class submarines utilize multiple discrete tri-axial (i.e. three-axes) magnetic field (B-field) sensors that measure the localized B-field surrounding the discrete sensors, which are permanently installed in the hull of the ship. The current B-field sensor of choice is a 3-axes Flux Gate Magnetometer. Unfortunately; the system performance of these discrete FGMs is adversely affected by local anomalies from a multitude of nearby magnetic sources/materials such as: electronic equipment, rotating machinery, structural welds, support beams, etc. The magnetic sensors required for CLDG have many stringent requirements including: high physical and electronic stability, low sensor noise, and high measurement accuracy over a range of temperatures and B-fields that are encountered during shipboard engineering spaces. The overall goal of the proposed Phase II effort is to synergistically combine two types of magnetic measurement systems that are not adversely affected by these local magnetic anomalies so that the correct input can be provided to the CLDG system and hence make the submarine less vulnerable to detection from its magnetic signature. The highly detailed and successful Phase I experimental investigation compared two separate integrated B-field measurement techniques: a) a Flux Gate Magnetometer (FGM) using discrete 3-axes FGM sensors and b) a true continuous Spatially Integrating Magnetometer (SIM). The primary Technical Objectives of the Phase II Base are to improve the B-field measurement sensitivity of the continuous SIM. To accomplish this task, a new digital based SIM version with superior SWaP, will replace the older analog SIM unit. Once the new digital SIM has been fabricated, e2P will synergistically combine the continuous SIM with the discrete FGM sensors using e2Ps proprietary Calibration Techniques. The combined approach will provide an unequaled SIM with superior performance enhancement over the entire dynamic range of operation compared to any competitor. This will result in the desired outcome of providing the correct input to the CLDG system when localized magnetic perturbations are present, thereby reducing the magnetic signature of the ship/submarine.

Benefit:
An anticipated potential commercial market opportunity for this technology is in proton therapy in the healthcare field. Proton therapy is now commonly used for the treatment of certain types of cancers. These proton therapy centers rely on compact curved accelerators with multiple C-shaped dipole magnets for beam steering. Since it is the Int(Bdl) measurement that is most important, e2Ps proposed Integrated Magnetometer could play an important role.

Keywords:
magnetic field, measurement sensors, Degaussing