SBIR-STTR Award

Development Of A Novel Composite Material Based On Monodisperse Glass Microspheres For Thermal Neutron Scintillation Detectors
Award last edited on: 12/6/2010

Sponsored Program
SBIR
Awarding Agency
NSF
Total Award Amount
$149,961
Award Phase
1
Solicitation Topic Code
-----

Principal Investigator
Kenneth Weston

Company Information

Nuclear Safeguards and Security Systems (AKA: NucSafe Inc)

601 Oak Ridge Turnpike
Oak Ridge, TN 37830
   (865) 220-5050
   inform@nucsafe.com
   www.nucsafe.com
Location: Single
Congr. District: 03
County: Anderson

Phase I

Contract Number: ----------
Start Date: ----    Completed: ----
Phase I year
2010
Phase I Amount
$149,961
This Small Business Innovation Research Phase I project will develop the technology needed for high performance neutron detectors that use Ce3+ activated 6Li glass in the form of monodisperse microspheres with strategically controlled dimensions and architecture. Current Ce3+/6Li glass scintillator technology has the potential to produce neutron detectors that are extremely sensitive, rugged, flexible in design geometry, have a large dynamic range (background to 10 Mcps), and do not contain toxic or regulated materials, but the glass also scintillates in response to gamma radiation, which is problematic since it can cause unacceptably high false neutron alarms. The proposed material to be developed will have significantly lower gamma sensitivity as compared to the bulk glass or optical fibers and will lead to a transformational impact on the performance that can be achieved as compared to existing neutron detection systems. The broader impact/commercial potential of this project includes filling a market need that is vitally important for the security of vulnerable nuclear weapons and materials, and for the prevention of illicit trafficking of these materials. The effectiveness of detection systems at high-risk border crossings, airports and seaports, as well as at nuclear weapons and components storage locations and research reactors, will be improved. Since neutrons are not emitted by most radionuclides used for medical or industrial purposes, the detection of neutrons is usually an unambiguous indicator of the presence of special nuclear materials (SNMs). Because the vast majority of neutron detection systems in existence today rely on 3He proportional counters and there is currently a global shortage of 3He, a suitable alternative neutron detection technology is urgently needed

Phase II

Contract Number: ----------
Start Date: ----    Completed: ----
Phase II year
----
Phase II Amount
----