SBIR-STTR Award

Squashing the Scope Superbug: A Disposable System for ERCP that Saves Patients from Bacterial Cross-Contamination
Award last edited on: 9/21/2022

Sponsored Program
SBIR
Awarding Agency
NIH : NIDDK
Total Award Amount
$1,157,591
Award Phase
2
Solicitation Topic Code
847
Principal Investigator
Joshua B Gafford

Company Information

EndoTheia Inc

111 Brookfield Avenue
Nashville, TN 37205
   N/A
   N/A
   www.endotheia.com
Location: Single
Congr. District: 05
County: Davidson

Phase I

Contract Number: 1R44DK126606-01
Start Date: 8/1/2020    Completed: 7/31/2022
Phase I year
2020
Phase I Amount
$617,640
The objective of this proposal is to create a new low-cost, disposable system that enables reliable, safe, standard endoscopes to replace expensive, customized duodenoscopes, which have recently been shown to cause infections at an alarming rate. Clinical signi?cance comes from the fact that 40,000 patients per year will be infected by unclean duodeno- scopes, among the 700,000/year who undergo endoscopic retrograde cholangiopancreatography (ERCP) in the USA alone. The reason for this is that duodenoscopes contain tiny moving parts, used to aim transendoscopic tools sideways at the endoscope tip, which harbor bacteria. In response to the alarming infection rates, in August 2019 the FDA issued a call-to-action for medical device manufactures to develop novel, disposable devices for ERCP, and for hospitals to rapidly adopt them once available. Our Innovation is to enable ERCP by augmenting a standard endoscope with a novel low-cost disposable steerable sheath/endcap system. Our innovative steerable sheath (which passes through the endoscope port) uses stiffness asymmetry in two thin-walled tubes to enable steering of trans-endoscopic instruments carried in its large central lumen. The tubes are attached at their tips, enabling the stiffness asymmetry to transform small axial tube motions into dexterous local bending at the endoscope tip. The result is an inexpensive, disposable device for dexterously steering the ?exible guidewires, cannulas, and sphincterotomes used in ERCP. At the endoscope tip, the sheath passes through a curved channel built into a custom endcap that (1) aims it sideways and (2) provides side-view-visualization via an integrated mirror. Our approach in Aim 1 is to design a clinically-ready version of our steerable sheath/cap system by optimizing tube mechanical properties while designing for scalable manufacturing. Aim 2 focuses on designing the end cap for optimal tool delivery and side-view mirror-based visualization. Aim 3 focuses on statistically powered experiments to compare our new device to standard duodenoscopes in terms of papilla cannulation rate, can- nulation time, and navigation time to the duodenum, and an animal pilot study to demonstrate in vivo usability. Success in these aims will strongly motivate the Phase III activities described in the Commercialization Strategy document (supported by private capital after the conclusion of this Phase II SBIR) where we complete the FDA 510(k) clearance process, and release our device to the commercial market.

Public Health Relevance Statement:
Narrative: Public Health Relevance Complex, dif?cult-to-sterilize duodenoscopes have recently been identi?ed as the source of approximately 40,000 infections per year in patients undergoing endoscopic retrograde cholangiopancreatography (ERCP), resulting in a call-to-action by the FDA to create new tools that prevent infections. EndoTheia is answering this call by creating a new low-cost, disposable, steerable device that enables safer ERCP interventions. Success in this research will solve the public health challenge of duodenoscope cross-contamination, sparing many patients from life-threatening infections.

Project Terms:
Adopted; American; Animals; Bacteria; base; Blood Vessels; Cannulas; Cannulations; Capital; Catheters; Clinical; clinically significant; commercialization; Complex; cost; Coupled; Custom; design; Devices; dexterity; Duodenoscopes; Duodenum; Elevator; Endoscopes; Endoscopic Retrograde Cholangiopancreatography; Engineering; experimental study; Family suidae; flexibility; Gastroscopes; Goals; Hospitals; in vivo; Infection; Infection prevention; infection rate; Injections; innovation; instrument; Intellectual Property; Intervention; Intestines; Intuition; Lasers; Lateral; Life; manufacturability; Manufacturer Name; mechanical properties; Mechanics; Medical Device; Modeling; Molds; Motion; novel; Patients; Pattern; Phase; Physicians; Pilot Projects; Polymers; Positioning Attribute; Privatization; Procedures; Process; prototype; Public Health; public health relevance; recruit; Research; response; Secure; Side; Small Business Innovation Research Grant; Source; Squash; success; Superbug; Surgeon; System; Thinness; Time; tongue papilla; tool; Torsion; Training; Tube; usability; Visualization; Work

Phase II

Contract Number: 5R44DK126606-02
Start Date: 8/1/2020    Completed: 7/31/2023
Phase II year
2021
Phase II Amount
$539,951
/:The objective of this proposal is to create a new low-cost, disposable system that enables reliable, safe,standard endoscopes to replace expensive, customized duodenoscopes, which have recently been shown tocause infections at an alarming rate.Clinical significance comes from the fact that 40,000 patients per year will be infected by unclean duodeno-scopes, among the 700,000/year who undergo endoscopic retrograde cholangiopancreatography (ERCP) in theUSA alone. The reason for this is that duodenoscopes contain tiny moving parts, used to aim transendoscopictools sideways at the endoscope tip, which harbor bacteria. In response to the alarming infection rates, in August2019 the FDA issued a call-to-action for medical device manufactures to develop novel, disposable devices forERCP, and for hospitals to rapidly adopt them once available.Our Innovation is to enable ERCP by augmenting a standard endoscope with a novel low-cost disposablesteerable sheath/endcap system. Our innovative steerable sheath (which passes through the endoscope port)uses stiffness asymmetry in two thin-walled tubes to enable steering of trans-endoscopic instruments carried inits large central lumen. The tubes are attached at their tips, enabling the stiffness asymmetry to transform smallaxial tube motions into dexterous local bending at the endoscope tip. The result is an inexpensive, disposabledevice for dexterously steering the flexible guidewires, cannulas, and sphincterotomes used in ERCP. At theendoscope tip, the sheath passes through a curved channel built into a custom endcap that (1) aims it sidewaysand (2) provides side-view-visualization via an integrated mirror.Our approach in Aim 1 is to design a clinically-ready version of our steerable sheath/cap system by optimizingtube mechanical properties while designing for scalable manufacturing. Aim 2 focuses on designing the endcap for optimal tool delivery and side-view mirror-based visualization. Aim 3 focuses on statistically poweredexperiments to compare our new device to standard duodenoscopes in terms of papilla cannulation rate, can-nulation time, and navigation time to the duodenum, and an animal pilot study to demonstrate in vivo usability.Success in these aims will strongly motivate the Phase III activities described in the Commercialization Strategydocument (supported by private capital after the conclusion of this Phase II SBIR) where we complete the FDA510(k) clearance process, and release our device to the commercial market.

Public Health Relevance Statement:
Narrative: Public Health Relevance Complex, difficult-to-sterilize duodenoscopes have recently been identified as the source of approximately 40,000 infections per year in patients undergoing endoscopic retrograde cholangiopancreatography (ERCP), resulting in a call-to-action by the FDA to create new tools that prevent infections. EndoTheia is answering this call by creating a new low-cost, disposable, steerable device that enables safer ERCP interventions. Success in this research will solve the public health challenge of duodenoscope cross-contamination, sparing many patients from life-threatening infections.

Project Terms:
© Copyright 1983-2024  |  Innovation Development Institute, LLC   |  Swampscott, MA  |  All Rights Reserved.