SBIR-STTR Award

Multi-Source E-Beam kV X-Ray Tube for Image-Guided Radiotherapy
Award last edited on: 11/18/19

Sponsored Program
SBIR
Awarding Agency
NIH : NCI
Total Award Amount
$2,299,533
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Douglas P Boyd

Company Information

TeleSecurity Sciences (AKA: TSS)

7391 Prairie Falcon Road Suite 150-B
Las Vegas, NV 89128
Location: Single
Congr. District: 04
County: Clark

Phase I

Contract Number: 1R43CA192498-01
Start Date: 1/1/15    Completed: 6/30/15
Phase I year
2015
Phase I Amount
$299,533
This project will lead to the development of an optimized X-ray tube with 19 focal spots that can be placed immediately below and around the multi-leaf collimator (MLC) of a radiotherapy system. By steering a focused electron beam (e-beam) on a series of 19 cooled tungsten targets in sequence, this system will provide a set of projection images that can be reconstructed into a 20 cm 20 cm 20 cm digital tomosynthesis (DTS) volume image that surrounds the radiation target. The projection X-rays are captured by a universal kV-MV imager that can record portal MV images interlaced with the sequence of tomographic kV images. Since the sources are positioned around the perimeter of the MLC, the resulting tomographic cross section images are aligned perpendicular to the axis of the therapy beam. This geometry is referred to as "Beam's Eye View" imaging. The DTS images will be used to provide precise reference coordinates of a tumor surface for programming of the MLC, in near real-time. The preliminary specifications for the system indicate that a repetition rate of1 volume image per second with near 1 mm spatial resolution will be possible. The multi-source e-beam X-ray tube will be developed by substantially the same premier team who developed the original Imatron EBCT scanners and the more recent e-beam luggage scanner. The e-beam team consisting of TeleSecurity Sciences, Inc. scientists, consultants, and vendors has partnered with the premier cone beam CT team at UC Davis along with a key Varian consultant, who are authorities on flat panel X-ray imagers, and in particular the kV-MV imager that will be used in this project to provide simultaneous MV portal imaging with interlaced kV DTS imaging of the tumor position. Phase 1 of the project will extend the preliminary work to more precisely define the final design specifications for a future commercial system that will be appropriate for the entire radiotherapy industry. Phase 2 funding will develop a suitable prototype of the multi-source e- beam X-ray tube which will demonstrate the feasibility and performance of the commercial system. The majority of radiotherapy vendors have provided guidance and letters of support for this project. The commercial implementation of the proposed system in future radiotherapy systems will permit treatment plans that will have far improved localization of radiation exposure within reduced margins beyond the apparent boundaries of a malignant mass with a corresponding reduction in exposure to surrounding normal structures. This will be especially important in treating tumors of the chest and upper abdomen during free breathing where periodic motion in the range of 2 cm to 5 cm is often encountered. [1]

Public Health Relevance Statement:


Public Health Relevance:
We propose a novel "Beam's Eye View" (BEV) digital tomosynthesis (DTS) imaging system for image-guided radiotherapy consisting of a kV multi-source electron beam (e-beam) X-ray tube and universal kV-MV imager, which will generate higher contrast images in real-time enabling better treatment local control for more patients with less collateral damage. The multi-source e-beam X-ray tube will be integrated into the radiotherapy gantry and provide 19 projection images needed for the BEV DTS imaging in less than 1 second. The BEV DTS images reconstructed from the projection images recorded by the universal kV-MV imager will be of high contrast resolution and be used to provide accurate tumor tracking information to the multi-leaf collimator in real-time with 1 Hz update rate. [1]

Project Terms:
Abdomen; Accounting; Address; Algorithms; Am 80; Anodes; arm; authority; base; Breathing; cancer imaging; Chest; Clinical; Collaborations; Collimator; Colon Carcinoma; commercialization; cone-beam computed tomography; cost; design; Development; digital; Dose; Dose-Rate; Electron Beam; empowered; Engineering; Ensure; Exposure to; Eye; Financial compensation; Funding; Future; Geometry; Goals; Health; Image; improved; Industry; Lead; Letters; Lung; Lung Neoplasms; Malignant - descriptor; malignant breast neoplasm; Malignant neoplasm of lung; Malignant neoplasm of prostate; meetings; Methods; millimeter; millisecond; Modification; Motion; Normal tissue morphology; novel; operation; Operative Surgical Procedures; Patients; Performance; Phase; Plant Leaves; Positioning Attribute; Procedures; Process; programs; prototype; public health relevance; Radiation; Radiation therapy; reconstruction; Rectal Cancer; Reporting; Resolution; Risk; Roentgen Rays; Safety; Scanning; Science; Scientist; Security; Series; Shapes; Source; Speed (motion); Spottings; Structure; Surface; System; Testing; Time; Toxic effect; treatment planning; Tube; tumor; Tungsten; Update; Vendor; Work

Phase II

Contract Number: 2R44CA192498-02
Start Date: 4/1/15    Completed: 4/30/18
Phase II year
2016
(last award dollars: 2017)
Phase II Amount
$2,000,000

This project will develop a commercial product that will enable for the first time realtime tumor tracking during radiotherapy at an attractive price point and with minimal interference with standard clinical practice. The key novel technology is an optimized multi-source X-ray tube with 19 focal spots that is placed below the multi-leaf collimator (MLC) of a radiotherapy system as shown below. By steering a focused electron beam (e-beam) on a series of 19 cooled tungsten targets in sequence, this system will provide a set of projection images that can be reconstructed into a 20 cm × 20 cm × 20 cm digital tomosynthesis (DTS) volume image that surrounds the radiation target. The projection X-rays are captured by a universal kV-MV imager that can record portal MV images interlaced with the sequence of tomographic kV images. Since the sources are positioned around the perimeter of the MLC, the resulting tomographic cross section images are aligned perpendicular to the axis of the therapy beam. This geometry is referred to as "Beam's Eye View" imaging. The DTS images will be used to provide precise reference coordinates of a tumor surface for programming of the MLC, in near real-time. The preliminary specifications for the system indicate that a repetition rate of 2-3 volume images per second with near 1 mm spatial resolution will be possible. The multi-source e-beam X-ray tube will be developed by substantially the same premier team who developed the original Imatron EBCT scanners and the more recent e-beam luggage scanner. The e-beam team consisting of TeleSecurity Sciences, Inc. scientists, consultants, and vendors has partnered with the premier cone beam CT team at UC Davis along with a key Varian consultant, who are authorities on flat panel X-ray imagers, and in particular the Side-view of the TumoTrakTM in a Truebeam gantry kV-MV imager that will be used in this project to provide simultaneous MV portal imaging with interlaced kV DTS imaging of the tumor position. Phase 1 of the project extended the preliminary work to more precisely define the final design specifications for a future commercial system that will be appropriate for the entire radiotherapy industry. Phase 2 funding will develop a suitable prototype of the multi-source eBeam X-ray tube which will demonstrate the feasibility and performance of the commercial system. The majority of radiotherapy vendors have provided guidance and letters of support for this project. The commercial implementation of the proposed system in future radiotherapy systems will permit treatment plans that will have far improved localization of radiation exposure within reduced margins beyond the apparent boundaries of a malignant mass with a corresponding reduction in exposure to surrounding normal structures. This will be especially important in treating tumors of the chest and upper abdomen during free breathing where periodic motion in the range of 2 cm to 5 cm is often encountered.

Public Health Relevance Statement:


Public Health Relevance:
We propose a novel "Beam's Eye View" (BEV) digital tomosynthesis (DTS) imaging system for image-guided radiotherapy consisting of a kV multi-source electron beam (e-beam) X-ray tube and universal kV-MV imager, which will generate higher contrast images in real-time enabling better treatment local control for more patients with less collateral damage. The multi-source e- Beam X-ray tube will be integrated into the radiotherapy gantry and provide 19 projection images needed for the BEV DTS imaging in less than 1/2 second. The BEV DTS images reconstructed from the projection images recorded by the universal kV-MV imager will be of high contrast resolution and be used to provide accurate tumor tracking information to the multi- leaf collimator in real-time with 1 Hz update rate.

NIH Spending Category:
Bioengineering; Cancer; Diagnostic Radiology; Lung; Lung Cancer; Radiation Oncology

Project Terms:
Abdomen; Accounting; authority; Breathing; cancer imaging; Characteristics; Chest; Clinical; clinical practice; Collimator; Colon Carcinoma; cone-beam computed tomography; contrast imaging; design; digital; Dose; Electron Beam; Ensure; evaluation/testing; Exposure to; Eye; Funding; Future; Geometry; Health; Image; image guided; image guided radiation therapy; imaging system; improved; Industry; Letters; Linear Accelerator Radiotherapy Systems; Lung Neoplasms; Malignant - descriptor; malignant breast neoplasm; Malignant neoplasm of lung; Malignant neoplasm of prostate; Motion; new technology; Normal tissue morphology; novel; Oncologist; Operative Surgical Procedures; Patients; Performance; Phase; Physiologic pulse; Plant Leaves; Positioning Attribute; Power Sources; Price; Production; programs; prototype; public health relevance; Radiation; Radiation therapy; Rectal Cancer; Reporting; Research; Resolution; Roentgen Rays; Safety; Scanning; Science; Scientist; Series; Side; Source; Spottings; Structure; Surface; System; temporal measurement; Testing; Time; Toxic effect; treatment planning; Tube; tumor; Tungsten; Update; Vendor; voltage; Wor