Bi-Frequency Pc-Mut Co-Linear Array for Ophthalmic ImagingAward last edited on: 4/18/19
Sponsored Program
STTRAwarding Agency
NIH : NEITotal Award Amount
$154,690Award Phase
1Solicitation Topic Code
-----Principal Investigator
Xuecang GengCompany Information
Blatek Industries Inc
2820 East College Avenue Suite F
State College, PA 16801
State College, PA 16801
(814) 231-2085 |
sales@blatek.com |
www.blatek.com |
Research Institution
North Carolina State University
Phase I
Contract Number: 1R41EY021392-01Start Date: 7/1/11 Completed: 6/30/12
Phase I year
2011Phase I Amount
$154,690Public Health Relevance:
The state of art commercial ultrasonic ophthalmic imaging technologies use 10-20 MHz probes with fixed focus and mechanical scanning to obtain ultrasound images with poor resolution in anterior segments. High frequency UBM is helpful in obtaining high resolution, but lack of field of depth and still requires mechanical scanning. Annular arrays addressed field of depth concern, but requires mechanical scanning and the resolution needs to be improved. High frequency linear arrays showed high resolution in azimuth and field of depth control via electronic scanning, but with poor resolution in elevation axis. To overcome these issues Blatek and the team proposes to integrate the novel piezo-crystal micromachined ultrasound transducer (PC-MUT) technology with the novel bi-frequency collinear array technology to develop broad band, highly sensitive PC-MUT bi-frequency collinear arrays for advanced ophthalmic imaging. The bi- frequency design considers both the high resolution requirements for anterior segment imaging and the field depth requirements for posterior and lens imaging. The novel co- linear configuration allows for electronic scanning and dynamic focusing at both azimuth and elevation directions. The proposed technology will also facilitate improved resolution of imaging and increased field of depth for pre-operative analysis of corrective procedures of the lens. In Phase I, a novel dual-layer, co-linear array interconnect fabrication technique will be developed to demonstrate the feasibility of a 64/64-element 17.5/35 MHz co-linear array for ophthalmic imaging. In Phase II, optimized 192/128- element bi-frequency (17.5/35 MHz) co-linear arrays will be developed and extensive eye imaging experiments will be performed using the USC digital beamforming system. In Phase III, Blatek and the phase II partners will seek to commercialize this technology.
Thesaurus Terms:
Address;Anterior;Bi Element;Bismuth;Cataract;Collaborations;Development And Research;Diagnosis;Echography;Echotomography;Electronics;Elements;Eye;Eye Diseases;Eyeball;Frequencies (Time Pattern);Frequency;Glaucoma;Image;Imaging Phantoms;Imaging Technology;Industry;Investigators;Loinc Axis 4 System;Mechanics;Medical Ultrasound;Operative Procedures;Operative Surgical Procedures;Ophthalmologic Surgical Procedures;Ophthalmological Surgery;Ophthalmological Surgical Procedures;Ophthalmologist;Performance;Phase;Procedures;Process;R &D;R&D;Research;Research Personnel;Researchers;Resolution;Scanning;Surgical;Surgical Interventions;Surgical Procedure;System;Systems Development;Techniques;Technology;Transducers;Ultrasonic;Ultrasonic Imaging;Ultrasonic Transducer;Ultrasonics;Ultrasonogram;Ultrasonography;Ultrasound Diagnosis;Ultrasound Medical Imaging;Ultrasound Test;Ultrasound Transducer;Universities;Work;Base;Cataractogenesis;Cataractous Lenses;Design;Designing;Diagnostic Ultrasound;Digital;Experience;Experiment;Experimental Research;Experimental Study;Eye Disorder;Eye Surgery;Glaucomatous;Imaging;Improved;Innovate;Innovation;Innovative;Lens;Lenses;Mechanical;Member;New Technology;Next Generation;Novel;Novel Technologies;Ophthalmopathy;Prototype;Research And Development;Research Study;Sonogram;Sonography;Sound Measurement;Surgery;Ultrasound;Ultrasound Imaging;Ultrasound Scanning
Phase II
Contract Number: ----------Start Date: 00/00/00 Completed: 00/00/00