SBIR-STTR Award

Compact Ct Robust To Patient Motion For The Neuro Icu And Or
Award last edited on: 7/19/10

Sponsored Program
SBIR
Awarding Agency
NIH : NINDS
Total Award Amount
$176,240
Award Phase
1
Solicitation Topic Code
-----

Principal Investigator
Matthew William Jacobson

Company Information

Xoran Technologies (AKA: Xoran X-Ray LLC)

5210 South State Road
Ann Arbor, MI 48108
   (734) 418-5100
   info@xorantech.com
   www.xorantech.com
Location: Single
Congr. District: 06
County: Washtenaw

Phase I

Contract Number: 1R43NS067745-01
Start Date: 4/15/10    Completed: 4/14/11
Phase I year
2010
Phase I Amount
$176,240
Recent advances in flat-panel detectors and microcomputers have enabled compact and mobile computed tomography (CT) imaging devices to be successful in dental and otolaryngology applications, and show promise for neurological imaging applications. However unsedated patients with neurological conditions tend to move during the scan which degrades image quality in the soft-tissue / brain viewing windows. This proposal presents an innovative method to compensate for patient movement to restore image quality for CT exams. The method consists of software algorithms to estimate and correct patient movement from the projection data, employing inexpensive and readily available radio-opaque markers. This technology has the potential to improve timeliness, safety, and reliability of neuro-imaging in the ICU, CCU, and OR. Example applications include monitoring or detecting bleeds and infarcts, evaluating brain shift and compression, placing ventricular shunt catheters, and deep brain stimulation. Phase 1 will be devoted to the development of the motion compensation method and to demonstrating adequate imaging performance. Test data will be obtained from a head phantom subject with simulated brain hemorrhages and with realistic, mechanically-induced movement on a testbed. An algorithm will be developed to accurately estimate subject movement from the x-ray projections of radio-opaque markers attached to the head. Another algorithm will be developed to reconstruct images, incorporating the motion estimates. End-to-end tests will be performed with clinician feedback. In phase 2, the proposed device will be streamlined, including algorithm speedup, to enable practical use in clinical settings. Clinical studies will be performed to evaluate and refine the method for commercial launch. The commercial opportunity for the system is estimated to be over 5000 systems in the USA over 10 years, which would lead to the creation of approximately 100 jobs.

Public Health Relevance:
Recently emergent compact CT devices can perform head CT scans directly in the ICU, CCU, and OR, and therefore have the potential to improve timeliness, safety, and reliability of neuro- imaging. An obstacle to fulfilling this potential is that these systems have longer scanning times than conventional CT devices, making imaging performance more vulnerable to patient motion. To overcome this obstacle, this project proposes to combine a highly compact, mobile flat panel CT system with a method for motion compensation.

Thesaurus Terms:
Accidents; Adverse Experience; Adverse Event; Algorithms; Aneurysm; Artifacts; Aspiration, Respiratory; Bleeding; Bone Tissue; Brain; Brain Hemorrhage; Breathing; Cat Scan, X-Ray; Cat Scan; Ct X Ray; Ct Scan; Catheters; Clinic; Clinical; Clinical Research; Clinical Study; Compensation; Computed Tomography; Computer Programs; Computer Software; Computerized Axial Tomography (Computerized Tomography); Computerized Tomography, X-Ray; Computers; Confined Spaces; Data; Deep Brain Stimulation; Dental; Detection; Development; Devices; Diagnosis; Emi Scan; Ear; Ear Structure; Encephalon; Encephalons; Equipment; Estimation Techniques; Ethics Committees, Research; Exhibits; Feedback; Financial Compensation; Funding; Goals; Hosp; Head; Head And Neck; Head And Neck, Pharynx; Head And Neck Structure; Hemorrhage; Hospitals; Human Resources; Human Volunteers; Irbs; Image; Image Reconstructions; Imaging Device; Imaging Procedures; Imaging Techniques; Imaging Tool; Implant; Incidence; Industry; Infarction; Inhalation; Inhaling; Inspiration, Respiratory; Institutional Review Boards; Intensive Care Units; Jobs; Lead; Life; Location; Manpower; Manufacturer; Manufacturer Name; Marketing; Measurement; Measures; Mechanics; Medical; Methods; Microcomputers; Monitor; Morbidity; Morbidity - Disease Rate; Morphologic Artifacts; Motion; Movement; Nasal; Nervous System, Brain; Neurologic; Neurological; Neurosurgeon; North America; Nose; Nose, Nasal Passages; Occupations; Operating Rooms; Operation; Operative Procedures; Operative Surgical Procedures; Oto/Rhino/Laryngology; Otolaryngology; Patients; Pb Element; Performance; Pharyngeal Structure; Pharynx; Pharynxs; Phase; Position; Positioning Attribute; Procedures; Process; Professional Postions; Radio-Opaque; Radioopaque; Recruitment Activity; Research Ethics Committees; Respiratory System, Nose, Nasal Passages; Sbir; Sbirs (R43/44); Safety; Sales; Scanning; Series; Shunt; Shunt Device; Simulate; Small Business Innovation Research; Small Business Innovation Research Grant; Software; Source; Specific Qualifier Value; Specified; Supervision; Surgical; Surgical Interventions; Surgical Procedure; System; System, Loinc Axis 4; Technics, Imaging; Technology; Testing; Throat; Time; Tomodensitometry; Tomography, Computed, Scanners; Tomography, Xray Computed; Ventricular; X-Ray Computed Tomography; Blood Loss; Body Movement; Catscan; Commercialization; Computed Axial Tomography; Computer Program/Software; Computerized Axial Tomography; Computerized Tomography; Cost; Deep Brain Stimulator; Detector; Experiment; Experimental Research; Experimental Study; Hazard; Heavy Metal Pb; Heavy Metal Lead; Hemorrhagic Stroke; Imaging; Improved; Infarct; Innovate; Innovation; Innovative; Inspiration; Meetings; Millimeter; Non-Compliance; Otorhinolaryngology; Personnel; Point Of Care; Public Health Relevance; Recruit; Research Study; Restraint; Shunts; Soft Tissue; Surgeon, Neuro-; Surgery

Phase II

Contract Number: ----------
Start Date: 00/00/00    Completed: 00/00/00
Phase II year
----
Phase II Amount
----