SBIR-STTR Award

Coaxial Everting Membrane Catheter Bronchoalveolar Lavag
Award last edited on: 10/6/06

Sponsored Program
SBIR
Awarding Agency
NIH : NHLBI
Total Award Amount
$197,875
Award Phase
1
Solicitation Topic Code
-----

Principal Investigator
William R Krause

Company Information

Bioengineering Consultants LTD (AKA: Flex Technology Inc~Orthopedic Designs Inc)

801 W Main Street Suite 108
Charlottesville, VA 22903
   (434) 979-4134
   bioe_consultant@yahoo.com
   N/A
Location: Single
Congr. District: 05
County: Charlottesville city

Phase I

Contract Number: 1R43HL083521-01A1
Start Date: 00/00/00    Completed: 00/00/00
Phase I year
2006
Phase I Amount
$197,875
Ventilator-Associated Pneumonia (VAP) is pneumonia that develops in a mechanically ventilated patient later than 48 hours after intubation. The longer a patient is intubated, the greater the chance that pneumonia will develop. Pneumonia is the second most common nosocomial infection in critically ill patients, impacting 27% of all critically ill patients and is the leading cause of death from hospital-acquired (nosocomial) infections. Eighty-six percent of nosocomial pneumonias (NP) are associated with mechanical ventilation and are termed ventilator associated pneumonia. Between 250,000 and 300,000 cases per year occur in the United States, alone which is an incidence rate of 5-10 cases per 1,000 hospital admissions. An important diagnostic procedure is a culture of the sputum or lung aspirate for accurate diagnosis and therapeutic evaluation of the cause of the pneumonia. However, sputum (lung, trachea or oropharyngeal secretions) is often contaminated by saliva, oropharyngeal organisms and squamous cells that are deposited on the catheter during passage through the mouth and trachea. There are no commercially available catheter systems that allow for the collection of uncontaminated sputum samples for the diagnosis of pneumonia. The total commercial market for this type of device is approximately 250,000 units at a retail cost of $100 per device. The specific aim of this proposal is to design, prototype and evaluate an innovative coaxial everting membrane catheter for bronchoalveolar lavage (referred to as the CEMBAL catheter and brush) for accurate sputum collection for diagnosis of pneumonia. It is our hypothesis that the CEMBAL catheter system will allow the quick and easy collection of uncontaminated sputum for better management of the VAP patient. We propose to compare the CEMBAL catheter with the CombiCath(r) and a standard suction catheter in a bench-top model to demonstrate the ability of the catheter to retrieve uncontaminated samples. Ventilator-Associated Pneumonia (VAP) is the second most common nosocomial infection in critically ill patients, impacting 27% of all critically ill patients and is the leading cause of death from hospital-acquired (nosocomial) infections. The proposed device will provide for the uncontaminated sampling of the lower lung aspirate for a more accurate diagnosis of the organism causing the pneumonia.

Thesaurus Terms:
artificial respiration, biomedical equipment development, clinical biomedical equipment, diagnostic catheterization, diagnostic respiratory lavage, lung lavage, medical complication, nosocomial infection, pneumonia, respirator computer program /software, critical care, evaluation /testing, iatrogenic disease, intensive care, mechanical stress, phantom model bioengineering /biomedical engineering

Phase II

Contract Number: ----------
Start Date: 00/00/00    Completed: 00/00/00
Phase II year
----
Phase II Amount
----