SBIR-STTR Award

Fast measurement of adult body volume in air
Award last edited on: 6/2/09

Sponsored Program
SBIR
Awarding Agency
NIH : NIDDK
Total Award Amount
$555,199
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Virgil E Johnson Jr

Company Information

Hydronautics Research Inc

7210 Pindell School Road
Fulton, MD 20759
   (301) 369-4202
   N/A
   N/A
Location: Single
Congr. District: 03
County: Howard

Phase I

Contract Number: 1R43DK045560-01
Start Date: 00/00/00    Completed: 00/00/00
Phase I year
1993
Phase I Amount
$49,976
We will develop an inexpensive device that rapidly measures the body density (in air) of non-infant children and adults, so a quantitative degree of obesity (body fat fraction) may be deduced. Such routine measurements should result in improved weight control programs with consequent reduction in the health risks associated with hypertension, cardiovascular disease, cancer, diabetes, and many other disorders. There are two known methods that have been proposed for the in-air measurement of body volume_principally for infants. One is based on air displacement and the intrinsic relationship between gas volume and pressure. Another method, using the Helmholtz resonator principal with excitation from a loud-speaker, has also been proposed for infants. Both methods are complex and highly sensitive to temperature. The new device also uses acoustic resonance principles, but eliminates problems related to temperature or humidity changes. It is expected that very accurate measurements can be made in much less than a minute with readout in body density and estimated percent body fat. The device should be inexpensive and a product desired and eventually required by most physicians. Specific aims of Phase I would include design and construction of a breadboard acoustic volume device to measure the volume of adults and optimize the system by measuring a range of known volumes of water. Some preliminary studies would also be conducted with some human volunteers.Awardee's statement of the potential commercial applications of the research: An inexpensive device capable of fast and reliable measurement of body volume (in air) should rapidly become standard equipment for most physicians. Routine measurement of body density and inferred lean body mass is expected to have a major influence on obesity treatment programs.National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)

Phase II

Contract Number: 2R44DK045560-02A1
Start Date: 00/00/00    Completed: 00/00/00
Phase II year
1995
(last award dollars: 1996)
Phase II Amount
$505,223

The long term objective is to provide an inexpensive device that rapidly measures the body density (in air) of adults so that a quantitative degree of obesity (body fat-fraction) may be deduced. Such routine measurements should result in improved weight control programs with consequent reduction in the health risks associated with hypertension, cardiovascular disease, cancer, diabetes, and many other disorders. The device measures body volume acoustically using the Helmholtz resonator principle with excitation by a thin air jet. The effects of temperature and humidity on the measurement are reduced by employing a second high frequency resonator. The device relies only on the measurement of acoustic signal frequency - not amplitude. Its simplicity, ruggedness and ease of use should make the measurement of fat fraction with the acoustic volumeter as standard as the patients weight.National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)