SBIR-STTR Award

MEMS-Based Volatile Organic Compound Monitor
Award last edited on: 10/8/2004

Sponsored Program
SBIR
Awarding Agency
EPA
Total Award Amount
$70,000
Award Phase
1
Solicitation Topic Code
-----

Principal Investigator
Dharanipal Doppalapudi

Company Information

Boston MicroSystems Inc (AKA: BMS)

30-H Sixth Road
Woburn, MA 01801
   (781) 933-5100
   bms@bostonms.com
   www.bostonms.com
Location: Single
Congr. District: 05
County: Middlesex

Phase I

Contract Number: ----------
Start Date: ----    Completed: ----
Phase I year
2004
Phase I Amount
$70,000
Boston MicroSystems, Inc. (BMS), proposes to develop a MicroElectroMechanical System (MEMS) based volatile organic compound (VOC) monitor by integrating analyte-specific polymer films with SiC-AlN microresonators. In this research project, BMS and the Naval Research Laboratory will integrate microresonators and polymer films with functional groups sensitive to aromatic compounds (e.g., benzene and toluene); halogenated hydrocarbons (e.g., methylene chloride); and aromatic alcohols (e.g., phenols and catechols). When exposed to hazardous air pollutants, the polymer films absorb the vapors, increasing their mass and resulting in a shift in the resonant frequency that is proportional to the pollutant concentration. The proposed MEMS-based sensor system is compact and robust, and has low cost and power requirements, and high sensitivity. By using an array with multiple sensors, each with high sensitivity to a particular pollutant, a high selectivity is achieved. The fully functional multichannel monitor is anticipated to be a battery-powered instrument consisting of a microresonator array, drive/sense electronics, rechargeable power supply, visual display, self-test, data storage, and an interface for data downloading. The proposed volatile organic monitor will provide a compact handheld or remotely operated instrument that enables rapid, real-time, low-cost measurement of multiple pollutant gases for industrial applications as well as for U.S. Environmental Protection Agency field agents. Primary applications include: (1) emissions monitoring in smokestacks and exhaust streams of chemical, pharmaceutical, and power-generating plants and refineries; (2) leak detection and process control near industrial machinery and processes with potential hazardous emissions; (3) monitoring a wide range of source locations in and around industrial facilities, as "residual risk fenceline monitors"; and (4) toxic dump sites. Other commercial applications include: (1) measuring VOC and hazardous air pollutant emissions from thin-film radiation-cured coating processes; (2) air quality control in buildings and sensors coupled with heating, ventilation, and air conditioning systems ("sick building syndrome"); and (3) air quality testing in confined chambers, tunnels, and mines. Supplemental

Keywords:
small business, SBIR, MicroElectroMechanical System, MEMS, volatile organic compound, VOC, monitor, SiC-AlN microresonator, polymer film, hazardous air pollutant, HAP, emissions, Naval Research Laboratory, EPA. , Ecosystem Protection/Environmental Exposure & Risk, POLLUTANTS/TOXICS, RFA, Scientific Discipline, Analytical Chemistry, Atmospheric Sciences, Chemicals, Environmental Chemistry, Environmental Monitoring, Monitoring/Modeling, HAPS, Phenol, Volatile Organic Compounds (VOCs), aerosol analyzers, air quality model, aromatic compounds, atmospheric chemistry, chemical characteristics, micro electromechanical system, microanalyzer, microsensors

Phase II

Contract Number: ----------
Start Date: ----    Completed: ----
Phase II year
----
Phase II Amount
----