SBIR-STTR Award

Lithium selective sensors with polymeric ionophores
Award last edited on: 6/2/2009

Sponsored Program
SBIR
Awarding Agency
NIH : NIMH
Total Award Amount
$522,745
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Paul Hale

Company Information

Bio-Tek Instruments Inc (AKA: BioTek Instruments Inc)

Box 998 Highland Park
Winooski, VT 05482
   (802) 655-4040
   sales@biotek.com
   www.biotek.com
Location: Single
Congr. District: 00
County: Chittenden

Phase I

Contract Number: 1R43MH052027-01
Start Date: 00/00/00    Completed: 00/00/00
Phase I year
1993
Phase I Amount
$75,232
The objective of this proposal is to develop a lithium ion-selective electrode, primarily for application to the clinical determination of lithium in patients undergoing therapy for manic depression. The lithium electrodes currently available are not sufficiently selective for lithium relative to sodium. The selectivity of these electrodes is determined by the metal affinities of organic molecules that function as ion carriers in polymer membranes. Improved lithium ionophores would enable molecules that function as ion carriers in polymer membranes. Improved lithium ionophores would enable automated analysis of whole blood with minimal handling of blood products by the operator. Similar electrodes for calcium, sodium and potassium are already in use in the clinical analyzer market. The major goal of the proposed project is to improve the lithium selectivity of the most promising family of lithium ionophores by covalent attachment of the ionophores to flexible ethylene oxide and siloxane polymers. This covalent attachment of the ionophores to a polymer backbone should help reduce aggregation and improve the lithium/sodium selectivity by preventing the formation of 2:1 complexes of the ionophore and sodium.Awardee's statement of the potential commercial applications of the research: Whole blood analysis instruments based on ISEs, such as those described in this proposal, will give faster results and will be safer than existing clinical laboratory methods. Portable automatic units could greatly expand the current billion dollar market for blood analyzers in clinical laboratories and hospitals. Lithium ISE technology is also applicable to quality control and environmental markets.National Institute of Mental Health (NIMH)

Phase II

Contract Number: 2R44MH052027-02
Start Date: 00/00/00    Completed: 00/00/00
Phase II year
1995
(last award dollars: 1996)
Phase II Amount
$447,513

We will develop lithium ion-selective sensors, primarily for application to the clinical determination of lithium in patients undergoing therapy for manic depression. The lithium electrodes currently available are not sufficiently selective for lithium relative to sodium. The selectivity of these electrodes is determined by the metal affinities of organic molecules that function as ion carriers in polymer membranes. Improved lithium ionophores would enable automated analysis of whole blood with minimal handling of blood products by the operator. Similar electrodes for calcium, sodium and potassium are already in use in the clinical analyzer market. The major goal of this project is to improve the lithium selectivity of the most promising family of lithium ionophores by covalent attachment of the ionophores to flexible ethylene oxide and siloxane polymers. This covalent attachment of the ionophores to a polymer backbone should help reduce aggregation and improve the lithium/sodium selectivity by preventing the formation of 2:1 complexes of the ionophore and sodium. During the phase II program, lithium-selective sensors will be developed using these new polymers in conjunction with conventional and solid-state ion-selective electrodes (ISEs) and ion-selective field effect transistors (ISFETs).National Institute of Mental Health (NIMH)