SBIR-STTR Award

Novel development of a pediatric Magnetic Resonance Imaging (MRI) scanner
Award last edited on: 12/11/2023

Sponsored Program
SBIR
Awarding Agency
NSF
Total Award Amount
$275,000
Award Phase
1
Solicitation Topic Code
IH
Principal Investigator
Efrain Torres

Company Information

Adialante LLC

1159 Gibbs Avenue
Saint Paul, MN 55108
   (773) 600-8453
   N/A
   www.adialante.com
Location: Single
Congr. District: 04
County: Ramsey

Phase I

Contract Number: 2023
Start Date: ----    Completed: 10/1/2023
Phase I year
2023
Phase I Amount
$275,000
This Small Business Innovation Research (SBIR) Phase I project focuses on the development of techniques that will facilitate the design and development of affordable, compact, and patient-friendly magnetic resonance imaging (MRI) systems. MRI systems are the preferred modality for a range of imaging types, notably pediatrics, due to their superior diagnostic capabilities, high resolution, and minimal side effects. However, traditional MRI experiences can be daunting for children due to the confined and noisy environment, often leading to alternatives such as the use of anesthesia for an MRI scan or the use of computerized tomography (CT), which exposes them to high levels of ionizing radiation. The objective of this project is to innovate novel techniques for developing a new generation of scanners, with a focus on creating child-friendly imaging experiences. These groundbreaking techniques have the potential to introduce new classes of MRI scanners, expand the imaging market, and democratize MRI systems to communities in need worldwide._x000D_ _x000D_ The intellectual merit of this project focuses on the development of B1 imaging approaches. While traditional MRI scanners rely on B0 gradient coils for spatial encoding, B1 coils have previously been shown to spatially encode, but they remain widely under-used and under-developed. The goal of this effort is to demonstrate the viability and expand upon the B1 imaging approach known as Frequency-modulated Rabi-Encoded Echoes (aka, FREE), specifically, frequency-encoded and phase-encoded FREE. FREE is unique from other B1 imaging approaches because of its high immunity to magnetic imperfections. FREE, unlike other approaches, can appropriately image in highly inhomogeneous (and inexpensive) magnets. A scanner built around FREE would take advantage of the cost savings that come with removing B0 gradient coils and from reducing the homogeneity of a magnet. An MRI scanner utilizing FREE would be more affordable, compact, and silent. This project will focus on demonstrating two- and three-dimensional imaging on a compact, affordable, and inhomogeneous 0.5 Tesla system, thereby demonstrating the capability of B1 imaging approaches._x000D_ _x000D_ This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.

Phase II

Contract Number: 2323231
Start Date: 9/30/2024    Completed: 00/00/00
Phase II year
----
Phase II Amount
----